Search results for "Glucose Measurement"

showing 5 items of 5 documents

Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Ty…

2019

AIMS To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. METHODS Ten participants with Type 1 diabetes [four women, mean ± sd age 31.4 ± 9.0 years, BMI 25.5±3.8 kg/m2 , HbA1c 55±7 mmol/mol (7.2±0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having sw…

AdultBlood GlucoseMalemedicine.medical_specialtyEndocrinology Diabetes and Metabolism030209 endocrinology & metabolismPhysical exerciseBiosensing Techniques03 medical and health sciencesYoung Adult0302 clinical medicineEndocrinologyInsulin Infusion SystemsInterquartile rangePredictive Value of TestsDiabetes mellitusInternal medicineInternal MedicinemedicineHumansInsulin030212 general & internal medicineExercise physiologyBlood Glucose MeasurementExerciseType 1 diabetesCross-Over StudiesDose-Response Relationship Drugbusiness.industryBlood Glucose Self-MonitoringEquipment Designmedicine.diseaseCrossover studyDiabetes Mellitus Type 1Equipment and SuppliesPredictive value of testsCardiologyFemalebusiness
researchProduct

Evaluation of CGMS® During Rapid Blood Glucose Changes in Patients with Type 1 Diabetes

2006

CGMS (Medtronic Minimed, Duesseldorf, Germany) allows continuous glucose monitoring. Recent studies with invasive monitoring techniques revealed discrepancies in blood glucose measurements obtained from different anatomical sites compared with those from the fingertip. The aim of this study was to investigate the CGMS and a device for alternative site testing (AST) during dynamic blood glucose changes and to compare these results with fingertip measurements.Twelve patients with type 1 diabetes (seven women, five men; age, 33.3 +/- 8.7 years) received a 75-g oral glucose load. Insulin was applied intravenously (rapid glucose decline) or subcutaneously (moderate glucose decline) in a dosage b…

AdultBlood GlucoseMalemedicine.medical_specialtyInjections SubcutaneousEndocrinology Diabetes and Metabolismmedicine.medical_treatmentEndocrinologyForearmDiabetes mellitusmedicineHumansHypoglycemic AgentsInsulinIn patientBlood Glucose MeasurementType 1 diabetesbusiness.industryBlood Glucose Self-MonitoringSite testingInsulinGlucose MeasurementMiddle Agedmedicine.diseaseSurgeryMedical Laboratory TechnologyDiabetes Mellitus Type 1medicine.anatomical_structureAnesthesiaInjections IntravenousFemalebusinessDiabetes Technology & Therapeutics
researchProduct

Impact of environmental temperature on skin thickness and microvascular blood flow in subjects with and without diabetes.

2006

Glucose measurement from different skin areas might be influenced by changes in skin texture due to several environmental confounders. Our study was performed to investigate the effect of changes in ambient temperature on skin thickness and microvascular skin blood flow in subjects with and without diabetes at the lower forearm.Thirteen subjects with diabetes and seven without diabetes participated in the study. The investigations were performed in a temperature- and humidity-controlled climatic chamber (EMPA, St. Gallen, Switzerland). Starting at 25 degrees C, the environmental temperature was changed in 4 degrees C steps every 40 min. Skin thickness was measured by an ultrasonic reflectio…

AdultMalemedicine.medical_specialtyEndocrinology Diabetes and MetabolismSkin thicknessMicrocirculationEndocrinologyEnvironmental temperatureForearmReference ValuesInternal medicineDiabetes mellitusmedicineDiabetes MellitusLaser-Doppler FlowmetryHumansSkinUltrasonographyintegumentary systembusiness.industryMicrocirculationGlucose MeasurementTemperatureBlood flowMicroclimateMiddle Agedmedicine.diseaseSurgeryMedical Laboratory Technologymedicine.anatomical_structureSkin textureCardiologyFemalebusinessBlood Flow VelocityDiabetes technologytherapeutics
researchProduct

Fabrication of a biocompatible and continuous glucose biosensor with the poly(3,4-ethylenedioxythiophene) modified electrode

2019

Abstract In this study, we have explored the potentiality of using GOx/AuNP/PEDOT(BSA)/Pt electrode as an implantable, long-lasting, and sensitive glucose biosensor. We have examined the performance of the electrode for glucose calibration with three electrochemical measurements, such as cyclic voltammetry, linear sweep voltammetry, as well as chronoamperometry, which all exhibited strong linear correlation between resulting signal and glucose concentration. In comparison, linear sweep voltammetry gave the best linear sensitivity, whose average was about 3.124 µA/mM/cm2 within a wide glucose concentration range from 0.416 to 50 mM. Meanwhile, the stability of the electrode was confirmed by …

Materials scienceGeneral Chemical EngineeringGlucose Measurement02 engineering and technologyGeneral ChemistryChronoamperometry010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical scienceschemistry.chemical_compoundchemistryPEDOT:PSSLinear sweep voltammetryElectrodeCyclic voltammetry0210 nano-technologyBiosensorPoly(34-ethylenedioxythiophene)Nuclear chemistryJournal of the Taiwan Institute of Chemical Engineers
researchProduct

Effects of prandial glycemic changes on objective fetal heart rate parameters

2000

Background. There is confusion in the literature about the potential effect of maternal glucose levels on the fetal heart rate (FHR) cardiotocographic interpretation.Methods. Study design: prospective clinical descriptive study. Subjects: 21 pregnant women with diabetes mellitus, 23 women with gestational diabetes and 18 healthy non-diabetic pregnant volunteers (control group). Treatment: maternal capillary glucose measurement and objective FHR analysis (Oxford System 8002) pre- and 1 h post-meal. Statistical analysis: descriptive statistics, Student t-tests and Pearson correlation studies.Results. Maternal capillary glucose levels ranged between 2.7–10.5 mmol/l pre-meal and 4.2–14.8 mmol/l…

medicine.medical_specialtyPregnancymedicine.diagnostic_testbusiness.industryObstetricsdigestive oral and skin physiologyGlucose MeasurementObstetrics and GynecologyGeneral Medicinemedicine.diseaseGestational diabetesPostprandialEndocrinologyInternal medicineDiabetes mellitusembryonic structuresHeart ratemedicineCardiotocographybusinessGlycemicActa Obstetricia et Gynecologica Scandinavica
researchProduct